TruSeq DNA Exome Contents & Storage

TruSeq Exome Kit
(24 Samples)(20020614)

TruSeq DNA Library Prep for Enrichment
Box 1, Store at -25°C to -15°C

Quantity

Reagent

Description

 

1 RSB Resuspension Buffer  
1 ATL2 A Tailing Mix  
1 LIG2 Ligation Mix 2  
1 STL Stop Ligation Buffer  
1 EPM Enhanced PCR Mix  
1 ERP3 End Repair Mix  
1 EDTA EDTA 0.5 M  
1 PPC PCR Primer Cocktail  
Box 2, Store at 2°C to 8°C

Quantity

Reagent

Description

 

1 SPB Sample Purification Beads  
TruSeq DNA Enrichment
8 Enrichments - Box 1, Store at -25°C to -15°C

Quantity

Reagent

Description

 

1 CT3 Capture Target Buffer 3  
3 NEM Enrichment Amplification Mix  
1 EE1 Enrichment Elution Buffer 1  
1 HP3 2 N NaOH or HP3  
2 PPC PCR Primer Cocktail  
1 SWS Streptavidin Wash Solution  
8 Enrichments - Box 2, Store at 2°C to 8°C

Quantity

Reagent

Description

 

1 ET2 Elute Target Buffer 2  
2 SMB Strepravidin Magnetic Beads  
TruSeq DNA Single Indexes, Store at -25°C to -15°C
Set A

Quantity

Index Name

Description

 

1 AD002 DNA Adapter Index 2  
1 AD004 DNA Adapter Index 4  
1 AD005 DNA Adapter Index 5  
1 AD006 DNA Adapter Index 6  
1 AD007 DNA Adapter Index 7  
1 AD0012 DNA Adapter Index 12  
1 AD0013 DNA Adapter Index 13  
1 AD0014 DNA Adapter Index 14  
1 AD0015 DNA Adapter Index 15  
1 AD0016 DNA Adapter Index 16  
1 AD0018 DNA Adapter Index 18  
1 AD0019 DNA Adapter Index 19  
Set B

Quantity

Index Name

Description

 

1 AD001 DNA Adapter Index 1  
1 AD003 DNA Adapter Index 3  
1 AD008 DNA Adapter Index 8  
1 AD009 DNA Adapter Index 9  
1 AD0010 DNA Adapter Index 10  
1 AD0011 DNA Adapter Index 11  
1 AD0020 DNA Adapter Index 20  
1 AD0021 DNA Adapter Index 21  
1 AD0022 DNA Adapter Index 22  
1 AD0023 DNA Adapter Index 23  
1 AD0025 DNA Adapter Index 25  
1 AD0027 DNA Adapter Index 27  
Exome Panel (45Mb), Store at -25°C to -15°C

Quantity

Reagent

Description

 

4 CEX Coding Exome Oligos  

TruSeq Exome Kit
(96 Samples)(20020615)

TruSeq DNA Library Prep for Enrichment
Box 1, Store at -25°C to -15°C

Quantity

Reagent

Description

 

3 RSB Resuspension Buffer  
2 ATL2 A Tailing Mix  
1 LIG2 Ligation Mix 2  
1 STL Stop Ligation Buffer  
2 EPM Enhanced PCR Mix  
2 ERP3 End Repair Mix  
1 EDTA EDTA 0.5 M  
2 PPC PCR Primer Cocktail  
Box 2, Store at 2°C to 8°C

Quantity

Reagent

Description

 

4 SPB Sample Purification Beads  
TruSeq DNA Enrichment
8 Enrichments - Box 1, Store at -25°C to -15°C

Quantity

Reagent

Description

 

1 CT3 Capture Target Buffer 3  
3 NEM Enrichment Amplification Mix  
1 EE1 Enrichment Elution Buffer 1  
1 HP3 2 N NaOH or HP3  
2 PPC PCR Primer Cocktail  
1 SWS Streptavidin Wash Solution  
8 Enrichments - Box 2, Store at 2°C to 8°C

Quantity

Reagent

Description

 

1 ET2 Elute Target Buffer 2  
2 SMB Strepravidin Magnetic Beads  
TruSeq DNA CD Indexes (96 indexes, 96 samples), Store at -25°C to -15°C

Quantity

Reagent

Description

 
1 DAP DNA Adapter Plate, 96plex  
Exome Panel (45Mb), Store at -25°C to -15°C

Quantity

Reagent

Description

 

4 CEX Coding Exome Oligos